OVP-SE II Plus | ||
---|---|---|
Image | ![]() | |
Model | OVP-SE II Plus | |
Power Supply | Voltage | 100-240 VAC |
Voltage fluctuation | Within ±10% | |
Frequency | 50/60 Hz | |
Frequency fluctuation | Within ±3 Hz | |
Consumption electric power | 75VA | |
Fuse | 4 A, 250 V Ø5.0 × 20.0 mm | |
Size | Dimensions & Weight | 320(W) × 500(L) × 152(H) mm, 10.3kg |
Classification | Type of protection against electric shock | Class I |
Degree of protection against electric shock of applied part | ||
Degree of protection against explosion | ||
Observation | Video signal output | VBS composite (PAL), Y/C, HDMI, HD-SDI, DVI-D (simultaneous) |
Video signal input | VBS composite (PAL), HDMI | |
White balance | Auto via front panel switch | |
Color tone adjustment | R/B control: ±10 steps (via "System Setup") | |
Iris area selection | Average / Peak via front panel | |
Image enhancement mode | Sharpening of structure in images | |
Gamma correction | Adjustable via gamma value | |
Enhancement mode levels | Low, Med, High | |
Freeze screen display | Remote freeze key | |
Brightness selector | Adjustable via camera setup menu | |
Remote control | Freeze, Record, Light, WB, mBLU, etc. | |
mBLU | Switch to white or blue light | |
External Storage | USB Memory Stick | |
Documentation | Patient Data | Name, Sex, Age, DOB, Comments |
Display record state | Date/time (internal clock) | |
Pre-procedural data | Up to 40 patients | |
Image storage & retrieval | Memorization of selected setting | The following setting on the front panel are stored even when the video processor is turned OFF- System Setup, Setting the image record, Patient Data, Colour Tone, White Balance. |
Memory Backup | Lithium Battery | 5-year life |
Illumination | LED (White) | At Endoscope tip |
Air Feeding Method | Pump | Diaphragm type |
Airow | Low / High / Stop | |
Airow Pressurization | Air pressurization of detachable water container |
OVP-SE II | ||
---|---|---|
Image | ![]() | |
Model | OVP-SE II | |
Power Supply | Voltage | 100-240 VAC |
Voltage fluctuation | Within ±10% | |
Frequency | 50/60 Hz | |
Frequency fluctuation | Within ±3 Hz | |
Consumption electric power | 75VA | |
Fuse | 4 A, 250 V Ø5.0 × 20.0 mm | |
Size | Dimensions & Weight | 320(W) × 500(L) × 152(H) mm, 10.3kg |
Classification | Type of protection against electric shock | Class I |
Degree of protection against electric shock of applied part | ||
Degree of protection against explosion | ||
Observation | Video signal output | VBS composite (PAL), Y/C, HDMI, HD-SDI, DVI-D (simultaneous) |
Video signal input | VBS composite (PAL), HDMI | |
White balance | Auto via front panel switch | |
Color tone adjustment | R/B control: ±10 steps (via "System Setup") | |
Iris area selection | Average / Peak via front panel | |
Image enhancement mode | Sharpening of structure in images | |
Gamma correction | Adjustable via gamma value | |
Enhancement mode levels | Low, Med, High | |
Freeze screen display | Remote freeze key | |
Brightness selector | Adjustable via camera setup menu | |
Remote control | Freeze, Record, Light, WB, mBLU, etc. | |
mBLU | Switch to white or blue light | |
External Storage | USB Memory Stick | |
Documentation | Patient Data | Name, Sex, Age, DOB, Comments |
Display record state | Date/time (internal clock) | |
Pre-procedural data | Up to 40 patients | |
Image storage & retrieval | Memorization of selected setting | The following setting on the front panel are stored even when the video processor is turned OFF- System Setup, Setting the image record, Patient Data, Colour Tone, White Balance. |
Memory Backup | Lithium Battery | 5-year life |
Illumination | LED (White) | At Endoscope tip |
Air Feeding Method | Pump | Diaphragm type |
Airow | Low / High / Stop | |
Airow Pressurization | Air pressurization of detachable water container |
OVP-S3 | ||
---|---|---|
Image | ![]() | |
Model | OVP-S3 | |
Power Supply | Voltage | 100-240 VAC |
Voltage fluctuation | Within ±10% | |
Frequency | 50/60 Hz | |
Frequency fluctuation | Within ±3 Hz | |
Consumption electric power | 75VA | |
Fuse | 4 A, 250 V Ø5.0 × 20.0 mm | |
Size | Dimensions & Weight | 320(W) × 500(L) × 152(H) mm, 10.3kg |
Classification | Type of protection against electric shock | Class I |
Degree of protection against electric shock of applied part | ||
Degree of protection against explosion | ||
Observation | Video signal output | VBS composite (PAL), Y/C, HDMI, HD-SDI, DVI-D (simultaneous) |
Video signal input | VBS composite (PAL), HDMI | |
White balance | Auto via front panel switch | |
Color tone adjustment | R/B control: ±10 steps (via "System Setup") | |
Iris area selection | Average / Peak via front panel | |
Image enhancement mode | Sharpening of structure in images | |
Gamma correction | Adjustable via gamma value | |
Enhancement mode levels | Low, Med, High | |
Freeze screen display | Remote freeze key | |
Brightness selector | Adjustable via camera setup menu | |
Remote control | Freeze, Record, Light, WB, mBLU, etc. | |
mBLU | Switch to white or blue light | |
External Storage | USB Memory Stick | |
Documentation | Patient Data | Name, Sex, Age, DOB, Comments |
Display record state | Date/time (internal clock) | |
Pre-procedural data | Up to 40 patients | |
Image storage & retrieval | Memorization of selected setting | The following setting on the front panel are stored even when the video processor is turned OFF- System Setup, Setting the image record, Patient Data, Colour Tone, White Balance. |
Memory Backup | Lithium Battery | 5-year life |
Illumination | LED (White) | At Endoscope tip |
Air Feeding Method | Pump | Diaphragm type |
Airow | Low / High / Stop | |
Airow Pressurization | Air pressurization of detachable water container |
Specifications | OVP-IN2 | OVP-EIN (New Series) | |
---|---|---|---|
Image | ![]() | ![]() | |
Power supply | |||
Rated voltage | 100 – 240 V AC | 100 – 240 V AC | |
Voltage fluctuation | Within ±10% | Within ±10% | |
Rated frequency | 50/60 Hz | 50/60 Hz | |
Frequency fluctuation | Within ±3 Hz | Within ±3 Hz | |
Rated input | 18 VA | 18 VA | |
Size | |||
Dimensions | 295 (L) × 300 (W) × 80 (H) mm | 295 (L) × 300 (W) × 80 (H) mm | |
Weight | 4.9 Kg Approx | 4.9 Kg Approx | |
Classification (medical electrical equipment) | |||
Type of protection against electric shock | Class I | Class I | |
Degree of protection against electric shock of applied part | Depends on the applied part. (The degree of protection against electric shock of this product is BF type if the mounting part to be connected to this product is BF type. Note that CF type is not compatible with this product.) | ||
Degree or protection against explosion | The video processor should be kept away from flammable gases. | ||
Mode of operation | Continuous operation | Continuous operation | |
Observation | |||
Video signal output | HDMI x 2, DVI-D x 2, Y/C x 1, VBS x 1 simultaneous output is possible. | HDMI x 2, DVI-D x 2, Y/C x 1, VBS x 1 simultaneous output is possible. | |
White balance | By pressing the white balance switch on the front panel, automatic white balance can be performed. | By pressing the white balance switch on the front panel, automatic white balance can be performed. | |
Color tone adjustment | The following color tone adjustments may by using the color gain on the "System setup" menu *"R" control ±5 steps *"G" control ±5 steps *"B" control ±5 steps | NA | |
Iris area selection | The area over which light is measure can be changed according the body part that is being observed. The following to choices can be made using the Iris mode selector on the keyboard. Average: Normal observation Peak: When focusing on and/or observing a small bright area. | NA | |
Image enhancement mode setting | Fine patterns or edges in the endoscopic images can be enhance electrically to increase the image sharpness. | Fine patterns or edges in the endoscopic images can be enhance electrically to increase the image sharpness. | |
Switching the enhancement modes | The enhancement level can be selected from 3 levels enhancement modes (Low, Med and High) using the image enhancement mode on the front button panel remote switch and keyboard. | The enhancement level can be selected from 3 levels enhancement modes (Low, Med and High) using the image enhancement mode on the front button panel. | |
Gamma correction | Gamma correction adjustments can be performed by adjusting the gamma value. | NA | |
Freeze screen display | The endoscopic image can be displayed as a frozen image, using the remote switch and keyboard. | The endoscopic image can be displayed as a frozen image, using the remote switch. | |
Brightness selector | The brightness can be adjusted using the brightness adjustment on the "System & Image setting" menu. | NA | |
Contrast selector | The contrast can be adjusted using the contrast adjustment on the "System & Image setting" menu. | NA | |
Remote control | The following functions can be controlled by the endoscope's remote switches (Light, White Balance, Freeze, Zoom, Record Video, Iris, Record Image, Enhancement, Image Size, mBLU, Remove Data, No Option) | The following functions can be controlled by the endoscope's remote switches (Freeze, Image Record) | |
mBLU | This mode is used to switch the normal mode to mBLU mode - 1 & mBLU mode - 2 | NA | |
Documentation | |||
Patient information | The following data can be displayed on the monitor: • Patient ID • Patient name • Gender • Age • Date of birth • Comment | NA | |
Display the record state | Date/time (build in clock) | NA | |
Pre-procedural patient data | The following patient data - ID number, Patient name, Sex, Age, Date of Birth. | NA | |
Scope information data | The following scope information can be displayed on the monitor • Scope Model No. • Serial No. • Insertion Tube Diameter • Channel Diameter • Distal End Diameter • Cumulative uses • User details | NA | |
USB ports | Keyboard & External Storage | 01 - External Storage | |
Recording format | Image | PNG | PNG |
Video | AVI | AVI | |
Memory backup | Number of User Settings User settings | Up to 5Nos. users | NA |
User Function Settings | Settings are held in video processor memory, even after video system is turned off. | NA | |
Illumination | LED | LED at endoscope tip | LED at endoscope tip |